With BF09/BF12 contactor

Shop By
View as List Grid

22 Items

Set Descending Direction
per page
  1. DOL STARTER M1P 400/50-60 9-14A
    £116.29 £96.91 As low as £104.66
    0 in stock. - If not in stock expect about 2-4 days
    DIRECT-ON-LINE-STARTERENCLOSED WITH THERMAL OVERLOAD RELAYWITH START AND STOP/RESET BUTTONSWITH BF09/BF12 CONTACTOR18A MAX (7.5KW AT 400V)IP65. CONTACTOR COIL VOLTAGE 400VAC 50/60HZ
  2. DOL STARTER M1P 400/50-60 6.3-10A
    £116.29 £96.91 As low as £104.66
    0 in stock. - If not in stock expect about 2-4 days
    DIRECT-ON-LINE-STARTERENCLOSED WITH THERMAL OVERLOAD RELAYWITH START AND STOP/RESET BUTTONSWITH BF09/BF12 CONTACTOR18A MAX (7.5KW AT 400V)IP65. CONTACTOR COIL VOLTAGE 230VAC 50/60HZ
  3. DOL STARTER M1P 400/50-60 4-6.5A
    £116.29 £96.91 As low as £104.66
    0 in stock. - If not in stock expect about 2-4 days
    DIRECT-ON-LINE-STARTERENCLOSED WITH THERMAL OVERLOAD RELAYWITH START AND STOP/RESET BUTTONSWITH BF09/BF12 CONTACTOR18A MAX (7.5KW AT 400V)IP65. CONTACTOR COIL VOLTAGE 230VAC 60HZ
  4. DOL STARTER M1P 400/50-60 2.5-4A
    £116.29 £96.91 As low as £104.66
    0 in stock. - If not in stock expect about 2-4 days
    DIRECT-ON-LINE-STARTERENCLOSED WITH THERMAL OVERLOAD RELAYWITH START AND STOP/RESET BUTTONSWITH BF09/BF12 CONTACTOR13A MAX (5.5KW AT 400V)IP65. CONTACTOR COIL VOLTAGE 400VAC 50/60HZ
  5. DOL STARTER M1P 400/50-60 1.6-2.5A
    £116.29 £96.91 As low as £104.66
    0 in stock. - If not in stock expect about 2-4 days
    DIRECT-ON-LINE-STARTERENCLOSED WITH THERMAL OVERLOAD RELAYWITH START AND STOP/RESET BUTTONSWITH BF09/BF12 CONTACTOR10A MAX (3 to 4KW AT 400V)IP65. CONTACTOR COIL VOLTAGE 400VAC 50/60HZ
  6. DOL STARTER M1P 400/50-60 1-1V6A
    £116.29 £96.91 As low as £104.66
    0 in stock. - If not in stock expect about 2-4 days
    DIRECT-ON-LINE-STARTERENCLOSED WITH THERMAL OVERLOAD RELAYWITH START AND STOP/RESET BUTTONSWITH BF09/BF12 CONTACTOR6.5A MAX (2.2 to 3KW AT 400V)IP65. CONTACTOR COIL VOLTAGE 400VAC 50/60HZ
  7. DOL STARTER M1P 400/50-60 0.63-1A
    £116.29 £96.91 As low as £104.66
    0 in stock. - If not in stock expect about 2-4 days
    DIRECT-ON-LINE-STARTERENCLOSED WITH THERMAL OVERLOAD RELAYWITH START AND STOP/RESET BUTTONSWITH BF09/BF12 CONTACTOR4A MAX (1.1 to 1.5KW AT 400V)IP65. CONTACTOR COIL VOLTAGE 400VAC 50/60HZ
  8. DOL STARTER M1P 230/50-60 9-14A
    £116.29 £96.91 As low as £104.66
    0 in stock. - If not in stock expect about 2-4 days
    DIRECT-ON-LINE-STARTERENCLOSED WITH THERMAL OVERLOAD RELAYWITH START AND STOP/RESET BUTTONSWITH BF09/BF12 CONTACTOR2.5A MAX (0.75KW AT 400V)IP65. CONTACTOR COIL VOLTAGE 400VAC 50/60HZ
  9. DOL STARTER M1P 230/50-60 6 3-10A
    £116.29 £96.91 As low as £104.66
    0 in stock. - If not in stock expect about 2-4 days
    DIRECT-ON-LINE-STARTERENCLOSED WITH THERMAL OVERLOAD RELAYWITH START AND STOP/RESET BUTTONSWITH BF09/BF12 CONTACTOR1.6A MAX (0.37 to 0.55KW AT 400V)IP65. CONTACTOR COIL VOLTAGE 400VAC 50/60HZ
  10. DOL STARTER M1P 230/50-60 4-6 5A
    £116.29 £96.91 As low as £104.66
    0 in stock. - If not in stock expect about 2-4 days
    DIRECT-ON-LINE-STARTERENCLOSED WITH THERMAL OVERLOAD RELAYWITH START AND STOP/RESET BUTTONSWITH BF09/BF12 CONTACTOR1A MAX (0.25KW AT 400V)IP65. CONTACTOR COIL VOLTAGE 400VAC 50/60HZ
  11. DOL STARTER M1P 230/50-60 2 5-4A
    £116.29 £96.91 As low as £104.66
    0 in stock. - If not in stock expect about 2-4 days
    DIRECT-ON-LINE-STARTERENCLOSED WITH THERMAL OVERLOAD RELAYWITH START AND STOP/RESET BUTTONSWITH BF09/BF12 CONTACTOR13A MAX (5.5KW AT 400V)IP65. CONTACTOR COIL VOLTAGE 230VAC 50/60HZ
  12. DOL STARTER M1P 230/50-60 1 6-2 5A
    £116.29 £96.91 As low as £104.66
    0 in stock. - If not in stock expect about 2-4 days
    DIRECT-ON-LINE-STARTERENCLOSED WITH THERMAL OVERLOAD RELAYWITH START AND STOP/RESET BUTTONSWITH BF09/BF12 CONTACTOR10A MAX (3 to 4KW AT 400V)IP65. CONTACTOR COIL VOLTAGE 230VAC 50/60HZ
  13. DOL STARTER M1P 230/50-60 1-1 6A
    £116.29 £96.91 As low as £104.66
    0 in stock. - If not in stock expect about 2-4 days
    DIRECT-ON-LINE-STARTERENCLOSED WITH THERMAL OVERLOAD RELAYWITH START AND STOP/RESET BUTTONSWITH BF09/BF12 CONTACTOR6.5A MAX (2.2 to 3KW AT 400V)IP65. CONTACTOR COIL VOLTAGE 230VAC 50/60HZ
  14. DOL STARTER M1P 230/50-60 0 63-1A
    £116.29 £96.91 As low as £104.66
    0 in stock. - If not in stock expect about 2-4 days
    DIRECT-ON-LINE-STARTERENCLOSED WITH THERMAL OVERLOAD RELAYWITH START AND STOP/RESET BUTTONSWITH BF09/BF12 CONTACTOR4A MAX (1.1 to 1.5KW AT 400V)IP65. CONTACTOR COIL VOLTAGE 230VAC 50/60HZ
  15. DOL STARTER M1P 230/60 6 3-10A
    £116.29 £96.91 As low as £104.66
    0 in stock. - If not in stock expect about 2-4 days
    DIRECT-ON-LINE-STARTERENCLOSED WITH THERMAL OVERLOAD RELAYWITH START AND STOP/RESET BUTTONSWITH BF09/BF12 CONTACTOR2.5A MAX (0.75KW AT 400V)IP65. CONTACTOR COIL VOLTAGE 230VAC 50/60HZ
  16. DOL STARTER M1P 220/60 6.3-10A
    £116.29 £96.91 As low as £104.66
    0 in stock. - If not in stock expect about 2-4 days
    DIRECT-ON-LINE-STARTERENCLOSED WITH THERMAL OVERLOAD RELAYWITH START AND STOP/RESET BUTTONSWITH BF09/BF12 CONTACTOR1A MAX (0.25KW AT 400V)IP65. CONTACTOR COIL VOLTAGE 230VAC 50/60HZ
  17. DOL STARTER M1P 120/60 6.3-10A
    £116.29 £96.91 As low as £104.66
    0 in stock. - If not in stock expect about 2-4 days
    DIRECT-ON-LINE-STARTERENCLOSED WITH THERMAL OVERLOAD RELAYWITH START AND STOP/RESET BUTTONSWITH BF09/BF12 CONTACTOR10A MAX (3 to 4KW AT 400V)IP65. CONTACTOR COIL VOLTAGE 230VAC 60HZ
  18. DOL STARTER M1P 110/50-60 4-6 5A
    £116.29 £96.91 As low as £104.66
    0 in stock. - If not in stock expect about 2-4 days
    DIRECT-ON-LINE-STARTERENCLOSED WITH THERMAL OVERLOAD RELAYWITH START AND STOP/RESET BUTTONSWITH BF09/BF12 CONTACTOR6.5A MAX (2.2 to 3KW AT 400V)IP65. CONTACTOR COIL VOLTAGE 230VAC 60HZ
  19. DOL STARTER M1P 024/50-60 9-14A
    £116.29 £96.91 As low as £104.66
    0 in stock. - If not in stock expect about 2-4 days
    DIRECT-ON-LINE-STARTERENCLOSED WITH THERMAL OVERLOAD RELAYWITH START AND STOP/RESET BUTTONSWITH BF09/BF12 CONTACTOR10A MAX (3 to 4KW AT 400V)IP65. CONTACTOR COIL VOLTAGE 120VAC 60HZ
  20. DOL STARTER M1P 024/50-60 2 5-4A
    £116.29 £96.91 As low as £104.66
    0 in stock. - If not in stock expect about 2-4 days
    DIRECT-ON-LINE-STARTERENCLOSED WITH THERMAL OVERLOAD RELAYWITH START AND STOP/RESET BUTTONSWITH BF09/BF12 CONTACTOR1.6A MAX (0.37 to 0.55KW AT 400V)IP65. CONTACTOR COIL VOLTAGE 110VAC 50/60HZ
  21. DOL STARTER M1P 400/50-60 13-18A
    £148.19 £123.49 As low as £133.37
    0 in stock. - If not in stock expect about 2-4 days
    DIRECT-ON-LINE-STARTERENCLOSED WITH THERMAL OVERLOAD RELAYWITH START AND STOP/RESET BUTTONSWITH BF09/BF12 CONTACTOR13AT MAX (5.5KW AT 400V)IP65. CONTACTOR COIL VOLTAGE 24VAC 50/60HZ
  22. DOL STARTER M1P 230/50-60 9-14A
    £148.19 £123.49 As low as £133.37
    0 in stock. - If not in stock expect about 2-4 days
    DIRECT-ON-LINE-STARTERENCLOSED WITH THERMAL OVERLOAD RELAYWITH START AND STOP/RESET BUTTONSWITH BF09/BF12 CONTACTOR10A MAX (3 to 4KW AT 400V)IP65. CONTACTOR COIL VOLTAGE 24VAC 50/60HZ
Shop By
View as List Grid

22 Items

Set Descending Direction
per page